- Ignition Off, disconnect the harness connector at the appropriate Q6 Camshaft Position Actuator Solenoid Valve.
- Test for 8-13 Ω between the control terminal A or 1 and the low reference circuit terminal B or 2
- If not between 8-13 Ω
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- If between 8-13 Ω
- If not between 8-13 Ω
- Test for infinite resistance between each terminal and the Q6 Camshaft Position Actuator Solenoid Valve housing.
- If not infinite resistance
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- If infinite resistance
- If not infinite resistance
- All OK