2-6 Clutch Applies
2-6 Pressure Control Solenoid 4
The 2-6 pressure control Solenoid 4 is commanded ON, allowing actuator feed fluid to enter the PCS 2-6 clutch fluid circuit. PCS 2-6 fluid is routed through orifice #32 and then to the 2-6 clutch regulator valve.
2-6 Clutch Regulator Valve
PCS 2-6 clutch fluid moves the 2-6 clutch regulator valve assembly against the 2-6 clutch regulator valve spring force to allow 2-6 clutch/1-2-3-4 clutch feed fluid to pass through the valve. The 2-6 clutch/1-2-3-4 clutch feed fluid is routed into the 2-6 clutch fluid circuit where it passes through orifice #46 and then to the spring end of the 2-6 clutch regulator valve, and to the 2-6 clutch.
2-6 Clutch
The 2-6 clutch fluid from the 2-6 clutch regulator valve is routed to the 2-6 clutch piston assembly. The 2-6 clutch fluid pressure moves the piston against 2-6 clutch spring force to apply the 2-6 clutch plates.