Conditions for Setting the DTC
P182E
Internal mode switch does not indicate a valid Park, Reverse, Neutral or Drive Range gear position for 7s.
P1915
Internal mode switch does not indicate Park or Neutral during the following sequence:
- Engine speed is 50 RPM or less for 0.25s or greater.
- Engine speed is 50-480 RPM for 0.07s or greater.
- Engine speed is 525 RPM or greater and the transmission input speed is 200 RPM or greater for 1.25s.