HVAC Control Components

HVAC Controls 

The HVAC controls contains all switches, which are required to control the functions of HVAC and serve as interface between the operator and the HVAC control module. The selected values are passed to the HVAC control module via LIN-Bus.

HVAC Control Module 

The HVAC control module is a GMLAN device that interfaces between the operator and the HVAC system to maintain and control desired air temperature and air distribution settings. The battery positive voltage circuit provides power that the HVAC control module uses for keep alive memory. If the battery positive voltage circuit loses power, all HVAC DTCs and settings will be erased from keep alive memory. The body control module (BCM), which is the vehicle mode master, provides a device ON-Signal. The HVAC control module provides blower, air delivery mode and air temperature settings.

The HVAC control module supports the following features:

Feature Availability
Afterblow Available if reprogrammed by the technician
Personalization Yes
Actuator Calibration Yes

Mode Actuator 

The mode actuator is a 5-wire stepper motor. The HVAC control module supplies a 12V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the mode flap into the calculated position in order to reach the selected position. The null point of the stepper motor will be calibrated, if the stepper motor is new. When the stepper motor is calibrated, the HVAC control module can drive the applicable coil to reach exactly the desired position of the flap.

Air Temperature Actuators 

The interior temperature can be selected separately for the driver and passenger. For this purpose, two stepper motors are used that regulates two mixed air flaps independently of each other. The air temperature actuators are 5-wire stepper motors. The HVAC control module supplies a 12V reference voltage to each stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The left air temperature actuator moves the left mixed air flap into the calculated position, in order to reach the selected temperature of the left temperature switch. The right air temperature actuator puts the right mixed air flap into the calculated position, in order to reach the selected temperature of the right temperature switch. The null point of the stepper motor will be calibrated, if the stepper motor is new. When the stepper motor is calibrated, the HVAC control module can drive the applicable coil to reach exactly the desired position of the flap.

Recirculation Actuator 

The recirculation actuator is a 5-wire stepper motor. The HVAC control module supplies a 12V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the recirculation flap into the calculated position in order to reach the desired position. The null point of the stepper motor will be calibrated, if the stepper motor is new. When the stepper motor is calibrated, the HVAC control module can drive the applicable coil to reach exactly the desired position of the flap.

Air Inlet Actuator 

The air inlet actuator is a 5-wire stepper motor. The HVAC control module supplies a 12V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor moves the air inlet flap into the calculated position, in order to reach the selected position. The null point of the stepper motor will be calibrated, if the stepper motor is new. When the stepper motor is calibrated, the HVAC control module can drive the applicable coil to reach exactly the desired position of the flap.

Blower Motor Control Module 

The blower motor control module controls the speed of the blower motor by increasing or decreasing the voltage drop on the ground side of the blower motor. The HVAC control module provides a low side pulse width modulation (PWM) signal to the blower motor control module via the blower motor speed control circuit. As the requested blower speed increases, the HVAC control module increases the amount of time that the speed signal is modulated to ground. As the requested blower speed decreases, the HVAC control module decreases the amount of time that the signal is modulated to ground.

Air Quality Sensor 

The HVAC control module detects exhaust gas by an air quality sensor. The air quality sensor is a 3-wire sensor with an ignition voltage circuit, a ground circuit and a signal circuit. The HVAC control module evaluates the information of the air quality sensor and closes the recirculation flap, while in automatic mode, as soon as the concentration of pollutants exceeds a predefined value.

Duct Temperature Sensors 

The air temperature sensors are 2-wire negative temperature co-efficient thermistors. The sensors operate within a temperature range of -40 to +85°C (-40 to +185°F). The sensors are installed in the air distribution ducts and measure the temperature of the air that streams from the ducts. The HVAC control module uses these values to calculate the mixed air flap position.

Evaporator Temperature Sensor 

The evaporator temperature sensor is a 2-wire negative temperature co-efficient thermistor. The sensor operates within a temperature range of -40 to +85°C (-40 to +185°F). The sensor is installed at the evaporator and measures its temperature. If the temperature drops under 3°C (38°F), the compressor will be switched off in order to prevent a frozen evaporator.

A/C Refrigerant Pressure Sensor 

The A/C refrigerant pressure sensor is a 3-wire piezoelectric pressure transducer. A 5V reference voltage, low reference, and signal circuits enable the sensor to operate. The A/C pressure signal can be between 0.2-4.8V. When the A/C refrigerant pressure is low, the signal value is near 0V. When the A/C refrigerant pressure is high, the signal value is near 5V. The engine control module (ECM) converts the voltage signal to a pressure value. When pressure is too high or too low, the ECM will not allow the A/C compressor clutch to engage.

A/C Compressor 

The A/C compressor is constantly belt driven. The performance of the A/C compressor is regulated per a lifting magnet in the A/C compressor. The HVAC control module supplies battery voltage to the A/C compressor. When the A/C switch is pressed, the HVAC control module provides a pulse width modulation (PWM) signal to the A/C compressor in order to command the performance of the A/C compressor. The performance of the A/C compressor is regulated according to adjusted interior temperature on the basis of characteristic lines. Therefore the HVAC control module grounds the A/C compressor with the PWM signal.

Ambient Light/Sunload Sensor 

The ambient light/sunload sensor includes the sunload sensor and passenger compartment temperature sensor.

This sensor assembly provides information about:

The sunload sensor is connected to ground and to a 12V clocked power supply through the HVAC control module. This clocked power supply is to power the sensor electronics and to work as a clock generator to the sunload sensor micro controller. The sensor uses a pulse signal for data identification and transferring the sun intensity measurement. At each positive transition from the clocked supply input, the sunload sensor micro controller will shift channels enabling new intensity measurement on the signal output to the HVAC control module. The signal voltage varies between 0-4V.

The passenger compartment temperature sensor is a negative temperature co-efficient thermistor. A signal and low reference circuit enables the sensor to operate. As the air temperature increases, the sensor resistance decreases. The sensor signal varies between 0-5V.

Bright or high intensity light causes the vehicles interior temperature to increase. The HVAC system compensates for the increased temperature by diverting additional cool air into the vehicle.

Heater Core Coolant Pump 

The primary purpose of the heater core coolant pump is to circulate engine coolant through the HVAC heater core when heat is required in the cabin for comfort. This normally happens when the vehicle is in an Auto Stop and the mechanical pump is not spinning. If the HVAC control module has determined heat is needed for the cabin, a request is sent via serial data to the engine control module to turn the pump ON. The engine control module controls the auxiliary coolant pump relay via the heater core coolant pump relay control circuit. The heater core coolant pump relay supplies voltage to the heater core coolant pump.