LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2015 >> Regal GS, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 7 (Hybrid/EV Energy Storage System) >> Diagnostic Information and Procedures >> DTC P0A80: Replace Hybrid/EV Battery Pack >> Circuit/System Verification

Circuit/System Verification

WARNING: This page is about a different variant/trim than selected.
WARNING:

Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure includes the following steps:

  • Identify how to disable high voltage.
  • Identify how to test for the presence of high voltage.
  • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.

Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:

  • Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.
  • Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.
    • Visually and functionally inspect the gloves before use.
    • Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.

Failure to follow the procedures may result in serious injury or death.

WARNING:

The eAssist battery pack assembly will utilize an exchange program. Please consult the most recent revision of bulletin/PI# PIC5520, available in Service Information (SI), for a list of approved eAssist battery pack assembly service procedures. Components that may be removed and serviced without exchanging the complete battery pack assembly are identified in the bulletin/PI. Please contact the GM Technical Assistance Center (1-877-446-8227) if you have any questions.

  1. Verify that no other DTCs are set.
  2. Verify DTC P0A80 is set.
    • If DTC P0A80 is set 
    1. Clear the DTC. Vehicle OFF, disconnect the 12V battery. Refer to Battery Negative Cable Disconnection and Connection (Without Start/Stop) .
    2. Wait 30 seconds. Reconnect the 12V battery. Refer to Battery Negative Cable Disconnection and Connection (Without Start/Stop) .
    3. Review and operate the vehicle according to the DTC Conditions for Running. Operate the vehicle for more than 10 minutes of city driving.
    4. Verify that DTC P0A80 does not reset.
      • If DTC P0A80 resets, replace the C4A Hybrid/EV Battery Section 1 and C4B Hybrid/EV Battery Section 2.
      • If DTC P0A80 does not reset.
    5. All OK.
    • If DTC P0A80 is not set 
  3. All OK.