3-5 Reverse Clutch Releases
Manual Valve
The manual valve is moved to the Neutral position and blocks line pressure from entering the reverse fluid circuit. Reverse fluid, from the 3-5-reverse clutch regulator valve, the clutch select valve, and the default override valve is opened to an exhaust passage at the manual valve.
3-5 R Pressure Control Solenoid
The 3-5 R PC solenoid is commanded OFF allowing PCS 3-5 reverse clutch fluid from the 3-5-reverse clutch regulator valve to exhaust.
3-5-Reverse Clutch Regulator Valve
PCS 3-5 reverse clutch fluid exhausts, allowing 3-5-reverse clutch regulator valve spring force to move the 3-5-reverse clutch regulator valve to the released position. This allows exhausting 3-5 reverse clutch fluid pressure to pass into the exhaust backfill circuit in order to assist the 3-5-reverse clutch piston spring to quickly release the 3-5-reverse clutch.
3-5-Reverse Clutch
3-5-reverse clutch spring force, assisted by exhaust backfill pressure, moves the 3-5-reverse clutch piston to release the 3-5-reverse clutch plates and force 3-5 reverse clutch fluid to exhaust from the 3-5-reverse and 4-5-6 clutch housing assembly. The exhausting 3-5 reverse clutch fluid pressure is routed to the 3-5-reverse clutch regulator valve where it enters the exhaust backfill circuit.
Clutch Select Valve
When reverse fluid exhausts from the clutch select shuttle valve, shift solenoid fluid continues to hold the clutch select valve against clutch select valve spring force allowing 3-5 reverse clutch feed fluid to exhaust into the reverse circuit.