Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the Q13 Evaporative Emission Vent Solenoid Valve, Ignition ON,
- Verify that a test lamp illuminates between the B+ circuit terminal A or 2 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2Ω in the B+ circuit end to end.
- If 2Ω or greater, repair the open/high resistance in the circuit.
- If less than 2Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, test all components connected to the B+ circuit for a short and replace as necessary.
- If the test lamp illuminates
- Verify that a test lamp does not illuminate between the B+ circuit terminal A or 2 and the control circuit terminal B or 1.
- If the test lamp illuminates
- Ignition OFF, remove the test lamp, disconnect the harness connector at the K20 engine Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K20 engine Control Module.
- If the test lamp does not illuminate
- Remove the test lamp.
- Verify the scan tool EVAP Vent Solenoid Valve Control Circuit High Voltage Test Status parameter is OK when commanding the EVAP Vent Solenoid Valve to ON (Not Venting) with a scan tool.
- If OK is not displayed
- Ignition OFF, disconnect the harness connector at the K20 engine Control Module, Ignition ON.
- Test for less than 1V between the control circuit and ground.
- If 1V or greater, repair the short to voltage on the circuit.
- If less than 1V, replace the K20 engine Control Module.
- If OK is displayed
- Install a 3A fused jumper wire between the control circuit terminal B or 1 and the B+ circuit terminal A or 2.
- Verify the scan tool EVAP Vent Solenoid Valve Control Circuit High Voltage Test Status parameter is Malfunction when commanding the EVAP Vent Solenoid Valve to ON (Not Venting) with a scan tool.
- If Malfunction is not displayed
- Ignition OFF, remove the jumper wire, disconnect the harness connector at the K20 engine Control Module.
- Test for less than 2Ω in the control circuit end to end.
- If 2Ω or greater, repair the open/high resistance in the circuit.
- If less than 2Ω replace the K20 engine Control Module.
- If Malfunction is displayed
- Test or replace the Q13 Evaporative Emission Vent Solenoid Valve.