Conditions for Running the DTC
WARNING: This page is about a different variant/trim than selected.
P2714
- DTC P0101, P0102, P0103, P0106, P0107, P0108, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0307, P0308, P0401, P042E, P0716, P0717, P0722, P0723, or P182E is not set.
- High side driver is enabled.
- Throttle position signal is valid.
- Ignition voltage is 9-32V.
- Transmission fluid temperature is -6.6°C (20°F) or greater.
- Engine speed is 400-7,500 RPM for 5s.
- Pressure control Solenoid 4 is commanded ON, applying the 2-6 clutch.
- Output speed is 100 RPM or greater, or the throttle position is greater than 0.5%.
- Runs continuously when above conditions are met.
P2715
- DTC P0101, P0102, P0103, P0106, P0107, P0108, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0307, P0308, P0401, P042E, P0716, P0717, P0722, P0723, or P182E is not set.
- Ignition voltage is 9-32V.
- Transmission output shaft speed is 100 RPM or greater, or throttle position is 0.5% or greater.
- Pressure control Solenoid 4 is commanded OFF, releasing the 2-6 clutch.
- Transmission fluid temperature is -6.6°C (20°F) or greater.
- Engine speed is 400-7,500 RPM for 5s.
- Engine torque is 45 N.m (33 lb ft) or greater.
- The attained range is not 1st gear.
- High side driver is enabled.
- Runs continuously when above conditions are met.