Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P182E
Internal mode switch does not indicate a valid Park, Reverse, Neutral, or Drive Range position for 7s.
P1915
Internal mode switch does not indicate Park or Neutral during the following sequence:
- Engine speed is less than 50 RPM for greater than 0.10s.
- Engine speed is 50-480 RPM for greater than 0.07s.
- Engine speed is greater than 500 RPM and the transmission input speed is greater than 100 RPM for greater than 1.25s.