Circuit/System Testing
- Ignition Off, disconnect the harness connector at the Q40 Turbocharger Bypass Solenoid Valve, ignition On.
- Verify a test lamp illuminates between the ignition circuit terminal 1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition Off.
- Test for less than 2Ω in the ignition circuit end to end.
- If 2Ω or greater, repair the open/high resistance in the circuit.
- If less than 2Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition Off, remove the test lamp.
- Test for infinite resistance between the ignition circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, test all components supplied by the fuse and replace as necessary.
NOTE:An short circuit in any component supplied by the fuse may cause the fuse to open and set a DTC when the component is activated.
- If the test lamp illuminates
- Verify that a test lamp does not illuminate between the control circuit terminal 2 and the ignition circuit terminal 1.
- If the test lamp illuminates
- Ignition Off, disconnect the harness connector at the K20 Engine Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K20 Engine Control Module.
- If the test lamp does not illuminate
- Remove the test lamp.
- Verify the scan tool Turbocharger Bypass Solenoid Valve Control Circuit High Voltage Test Status parameter is OK when commanding the Turbocharger Bypass Solenoid Valve Active with a scan tool.
- If OK is not displayed
- Ignition Off, disconnect the harness connector at the K20 Engine Control Module, ignition On.
- Test for less than 1V between the control circuit and ground.
- If 1V or greater, repair the short to voltage on the circuit.
- If less than 1V, replace the K20 Engine Control Module.
- If OK is displayed
- Install a 3A fused jumper wire between the control circuit terminal 2 and the ignition circuit terminal 1.
- Verify the scan tool Turbocharger Bypass Solenoid Valve Control Circuit High Voltage Test Status parameter is Malfunction when commanding the Turbocharger Bypass Solenoid Valve Active with a scan tool.
- If Malfunction is not displayed
- Ignition Off, disconnect the harness connector at the K20 Engine Control Module.
- Test for less than 2Ω in the control circuit end to end.
- If 2Ω or greater, repair the open/high resistance in the circuit.
- If less than 2Ω, replace the K20 Engine Control Module.
- If Malfunction is displayed
- Test or replace the Q40 Turbocharger Bypass Solenoid Valve.