K33 HVAC Control Module X3
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Available | Not Available | Not Available | Not Available | Not Available | Not Available | Not Available |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | - - |
GY/GN GY/D-GN |
516 516 |
Upper Left Air Temperature Sensor Signal (CJ2) Upper Left Air Temperature Sensor Signal (CJ2) |
I | - - |
| 2 | - - |
YE YE |
3167 3165 |
Mode Door Stepper Motor Control (3) Mode Door Stepper Motor Control (1) |
I | - - |
| 3 | - - |
WH/RD WH/RD |
3166 3165 |
Mode Door Stepper Motor Control (2) Mode Door Stepper Motor Control (1) |
I | - - |
| 4 | - - |
GY/BN GY/BN |
3167 3168 |
Mode Door Stepper Motor Control (3) Mode Door Stepper Motor Control (4) |
I | - - |
| 5 | - - |
D-GN/WH D-GN/WH |
3168 3166 |
Mode Door Stepper Motor Control (4) Mode Door Stepper Motor Control (2) |
I | - - |
| 6-8 | - | - | - | Not Occupied | - | - |
| 9 | - | BK | 407 | Sensor Low Reference | I | - |
| 10 | - | - | - | Not Occupied | - | - |
| 11 | - | D-GN | 3169 | Temp Door Stepper Motor Control (1) | I | - |
| 12 | - | WH/RD | 3170 | Temp Door Stepper Motor Control (2) | I | - |
| 13 | - | GY/RD | 3171 | Temp Door Stepper Motor Control (3) | I | - |
| 14 | - | RD/BK | 3172 | Temp Door Stepper Motor Control (4) | I | - |
| 15 | - - |
OG RD/BK |
7572 7572 |
HVAC Motor Supply Voltage HVAC Motor Supply Voltage |
I | - - |
| 16 | - | GY | 3173 | Air Inlet Door Stepper Motor Control (1) | I | - |
| 17 | - | D-BU/WH | 3174 | Air Inlet Door Stepper Motor Control (2) | I | - |
| 18 | - | BN/D-GN | 3175 | Air Inlet Door Stepper Motor Control (3) | I | - |
| 19 | - | RD/D-GN | 3176 | Air Inlet Door Stepper Motor Control (4) | I | - |
| 20 | - | BK/GY | 6137 | EVAP Core Temperature Sensor Signal | I | - |