  1. Ignition OFF and all vehicle systems OFF, disconnect the X2 harness connector at the K33 HVAC Control Module.
  2. Connect a test lamp between the ignition circuit terminal 9 and ground, Ignition ON.
  3. Verify the test lamp turns ON and OFF when commanding the Auxiliary Ignition Run Relay On and Off with a scan tool.
    • If the test lamp is always OFF 
    1. Ignition OFF, remove the test lamp, disconnect the harness connector at the K9 Body Control Module.
    2. Test for infinite resistance between the ignition circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance
    3. Test for less than 2Ω in the ignition circuit end to end.
      • If 2Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2Ω, replace the K9 Body Control Module.
    • If the test lamp is always ON 
    1. Ignition OFF, remove the test lamp, disconnect the harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1V between the ignition circuit and ground.
      • If 1V or greater, repair the short to voltage on the circuit.
      • If less than 1V, replace the K9 Body Control Module.
    • If the test lamp turns ON and OFF 
  4. Test or replace the K33 HVAC Control Module.