Circuit/System Description
The rear drive clutch solenoid valve is internal to the torque transfer device housing. The Rear Differential Clutch Control Module supplies battery voltage to the control circuit and ground to the low reference circuit of the solenoid valve. The solenoid valve is controlled by a pulse width modulation (PWM) signal. The solenoid valve controls the hydraulic pressure to the clutch package of the torque transfer device. The locking level of the torque transfer device depends on the engagement of the clutch package.