Component Testing
Fuel Door Latch
- Ignition OFF, disconnect the harness connector at the M97 fuel door lock actuator.
- Install a 25A fused jumper wire between one of the control terminals and 12V. Momentarily install a jumper wire between the other control terminal and ground. Reverse the jumper wires at least two times, the M97 fuel door lock actuator should perform the LOCK and UNLOCK function.
- If the actuator does not perform the LOCK and UNLOCK function
Replace the M97 fuel door lock actuator.
- If the actuator performs the LOCK and UNLOCK function
- If the actuator does not perform the LOCK and UNLOCK function
- All OK