Circuit/System Testing
- Ignition OFF, fully insert and remove the key in the ignition lock cylinder several times. Verify the scan tool Key In Cylinder Switch parameter changes from Active to Inactive.
- If the parameter is always Inactive, test the S39 ignition switch signal circuit terminal 4 and the B+ circuit terminal 2 for an open/high resistance or a short to ground. If all circuits test normal, replace the S39 ignition switch.
- If the parameter is always Active, test the S39 ignition switch signal circuit terminal 4 for a short to voltage. If all circuits test normal, replace the S39 ignition switch.
- If all circuits test normal, replace the K9 BCM.