Installation Procedure
- Carefully install the fluid pressure manual valve position switch (395).
- Install the control valve body bolts (375, 379, 381) that mount the TFP switch to the control valve body (300).
Tighten:
- Tighten the control valve body bolt (375) to 12 N.m (106 lb in).
- Tighten the control valve body bolt (379) to 16 N.m (12 lb ft).
- Tighten the control valve body bolt (381) to 8 N.m (70 lb in).
- Connect the transaxle wiring harness.
- Install the case side cover. Refer to Control Valve Body Cover Replacement .
- Reset the TAP values. Refer to Transmission Adaptive Functions .
NOTE:
When installing the TFP switch handle the switch carefully, the fluid pressure manual valve position switch is very delicate.
CAUTION:
Refer to Fastener Caution
.
NOTE:
It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.