Special Tools
J 34094-A: Thermal Element Height Gage
For equivalent regional tools, refer to Special Tools .
- Remove the thermo element plate pins (120).
- Remove the thermo element (121) and the thermo element plate (122).
- Use J 34094-A: height gage in order to set the height of the thermo element plate center pin (123).
- Install the thermo element plate (122).
- Use J 34094-A: height gage in order to set the height of the thermo element plate pin (120) that is farthest from the accumulators.
- Use J 34094-A: height gage in order to set the height of the second thermo element plate pin (120).
- Carefully install the thermo element (121) between the two thermo element plate pins (120).
- The V in the thermo element (121) must contact the thermo element plate (123).