LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2008 >> Enclave CX, AWD >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transmission - 6T70/6T75 - Removal & Installation, Service, Overhaul, Troubleshooting & Diagnosis >> Repair Instructions - Off Vehicle >> Manual Shift Detent Lever with Shaft Position Switch Assembly and Park Pawl Actuator Removal

Manual Shift Detent Lever with Shaft Position Switch Assembly and Park Pawl Actuator Removal

Fig 1: Identifying Manual Shift Detent Lever With Shaft Position Switch Assembly & Park Pawl Actuator
GM1737805Courtesy of GENERAL MOTORS CORP.
Callout Component Name
1 Park Pawl Actuator Bracket Bolt M6 x 25 (Qty: 2)
2 Park Pawl Actuator Bracket
3 Park Pawl Shaft
4 Park Pawl
5 Park Pawl Spring
6 Park Pawl Actuator Guide Pin
7 Park Pawl Actuator Guide
8 Manual Shift Detent Lever Pin
Tip: 
  • Use a small nail puller or other suitable tool.
  • Discard the pin. The pin is not reusable.

Special Tools

  • J 6125-1B  Slide Hammer with Adapter
  • J 23129  Universal Seal Remover. See Special Tools .
9 Manual Shaft Detent (w/Shift Position Switch) Lever Assembly
Tip:  Rotate the assembly counterclockwise so the actuator rod will fit through the case opening.
10 Park Pawl Actuator Assembly