LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2008 >> Allure CXL >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 3 (Engine Mechanical - 5.3L) >> Diagnostic Information and Procedures >> Cylinder Deactivation (Active Fuel Management) Valve Lifter Oil Manifold Diagnosis and Testing (5.3L) >> Diagnosis and Testing

Diagnosis and Testing

WARNING: This page is about a different variant/trim than selected.
Fig 1: Identifying Displacement On-Demand Tester
GM1479848Courtesy of GENERAL MOTORS CORP.

The manifold bench test provides a maximum 206 kPa (30 psi) of filtered shop air to the manifold and will test each solenoid/valve for the following conditions:

  1. Individually depress each of the buttons 1-4 on the EN-46999  in order to activate each of the solenoid/valves. When activating each solenoid/valve, a loud click should be heard from the solenoid and an increased amount of air will exit the outlet ports.
    • Button 1 will energize the solenoid/valve 1 for engine cylinder number 1.
    • Button 2 will energize the solenoid/valve 2 for engine cylinder number 4.
    • Button 3 will energize the solenoid/valve 3 for engine cylinder number 6.
    • Button 4 will energize the solenoid/valve 4 for engine cylinder number 7.
  2. Fig 2: Identifying Manifold Lift Caution
    GM1536553Courtesy of GENERAL MOTORS CORP.
  3. Do not lift the manifold assembly by the electrical lead frame.
  4. Fig 3: Identifying Displacement On-Demand Tester Air Adapter
    GM1402182Courtesy of GENERAL MOTORS CORP.
  5. Install the EN-46999-1  (1) to the manifold. See Special Tools .
  6. NOTE: Refer to Fastener Notice .
  7. Install 2 of the manifold bolts (2) to the EN-46999-1  . See Special Tools .

    Tighten:  Tighten the bolts to 25 N.m (18 lb ft).

  8. Fig 4: View Of Connecting Of Tester
    GM1402184Courtesy of GENERAL MOTORS CORP.
  9. Connect the air out hose (2) of the EN-46999  (5) to the EN-46999-1  (1). See Special Tools . Verify the air supply switch (4) is in the off position.
  10. Connect the air in hose (6) of the EN-46999  (5) to a shop air source.
  11. Connect the 12-volt power supply connectors (7) of the EN-46999  (5) to a 12-volt power supply. Verify the Power light (8) on the tool is illuminated. If the light on the tool is not illuminated when connected to a 12-volt power supply, test and/or replace the 3 amp fuse.
  12. Connect the EN-46999-5  power cable (3) to the electrical connector of the manifold. See Special Tools .
  13. Fig 5: View Of Bleed Holes & Outlet Ports
    GM1479849Courtesy of GENERAL MOTORS CORP.
  14. Turn the air supply switch of the EN-46999  to the ON position. With the air supply connected to the manifold assembly and the solenoid/valves in the closed position, a limited amount of air will exit each of the bleed holes (3) and outlet ports (1, 2) of the manifold.
  15. Fig 6: View Of Solenoid/Valves 1 & 4
    GM1479850Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: The manifold must be tested in the proper position to ensure the solenoid/valves operate as designed.
  16. Position the manifold assembly onto a bench at a 45 degree angle in order to test solenoid/valves 1 and 4.
  17. Depress button number 1 on the tool to activate solenoid/valve 1. With button 1 depressed, the solenoid/valve (1) should open, allowing an increased amount of air to exit the outlet ports (2) of the manifold.
  18. Depress button number 4 on the tool to activate solenoid/valve 4. With button 4 depressed, the solenoid/valve (4) should open, allowing an increased amount of air to exit the outlet ports (3) of the manifold.
  19. Fig 7: View Of Solenoid/Valves 2 & 3
    GM1479851Courtesy of GENERAL MOTORS CORP.
  20. Reposition the manifold assembly onto a bench at a 45 degree angle in order to test solenoid/valves 2 and 3.
  21. Depress button number 2 on the tool to activate solenoid/valve 2. With button 2 depressed, the solenoid/valve (2) should open, allowing an increased amount of air to exit the outlet ports (4) of the manifold.
  22. Depress button number 3 on the tool to activate solenoid/valve 3. With button 3 depressed, the solenoid/valve (3) should open, allowing an increased amount of air to exit the outlet ports (1) of the manifold.
  23. When the test is completed, turn the air source switch on the EN-46999  to the off position and disconnect the tool from the 12-volt power supply, shop air source and manifold assembly.
  24. If after testing, it has been determined that 1 or more of the solenoid/valves is not functioning properly, replace the manifold as an assembly.
  25. If after testing, it has been determined that the solenoid/valves are functioning properly, replace the valve lifters, as required. Both intake and exhaust lifters should be replaced in pairs.