Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the engine oil pressure (EOP) sensor.
  2. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal B and ground.
    • If less than the specified range, test the 5-volt reference circuit terminal B for a short to ground or an open/high resistance. If the circuit tests normal, replace the engine control module (ECM).
  3. Install a 3-amp fused jumper wire between the signal circuit terminal C and the 5-volt reference circuit terminal B. Verify the scan tool Engine Oil Pressure Sensor parameter is greater than 550 kPa (80 psi).
    • If less than the specified range, test the signal circuit terminal C for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
  4. If all circuits test normal, test or replace the EOP sensor.