LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Lucerne CX >> Repair and Diagnosis >> External Pages >> Different car >> Section 90 (Lighting Systems) >> Diagnostic Information and Procedures >> Fog Lamps Always On

Fog Lamps Always On

WARNING: This page is about a different car, the 2006 Buick LaCrosse and 2006 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
Fog Lamps Always On

Step Action Yes No
Schematic Reference: Fog Lights Schematics 
Connector End View Reference: Master Electrical Component List
1 Did you perform the Diagnostic System Check - Vehicle? Go to Step 2  Go to Diagnostic System Check - Vehicle
2
  1. Turn ON the ignition, with the engine OFF.
  2. Place the fog lamp switch in the OFF position.
  3. Place the headlamp switch in the OFF position.
Do the fog lamps remain illuminated?
Go to Step 3  Go to Testing for Intermittent Conditions and Poor Connections
3 Disconnect the FOG LP relay.
Did the fog lamps turn OFF?
Go to Step 4  Go to Step 8 
4
  1. Reinstall the FOG LP relay.
  2. Disconnect the lamp switch assembly.
Do the fog lamps remain illuminated?
Go to Step 5  Go to Step 10 
5 Disconnect the body control module (BCM) connector C3.
Do the fog lamps remain illuminated?
Go to Step 6  Go to Step 9 
6 Disconnect the BCM connector C1.
Do the fog lamps remain illuminated?
Go to Step 7  Go to Step 12 
7 Test for a short to ground in the fog lamp relay control circuit. Refer to Circuit Testing and Wiring Repairs .
Did you find and correct the condition?
Go to Step 13  Go to Step 11 
8 Repair a short to battery positive voltage in the fog lamp voltage supply circuit. Refer to Circuit Testing and Wiring Repairs .
Did you complete the repair?
Go to Step 13  -
9 Repair a short to ground in the fog lamp switch signal circuit. Refer to Circuit Testing and Wiring Repairs .
Did you complete the repair?
Go to Step 13  -
10 Replace the lamp switch assembly. Refer to Headlamp Switch Replacement .
Did you complete the repair?
Go to Step 13  -
11 Replace the FOG LP relay. Refer to Relay Replacement (Within an Electrical Center) or Relay Replacement (Attached to Wire Harness) .
Did you complete the replacement?
Go to Step 13  -
12 Replace the BCM. Refer to Control Module References for replacement, setup and programming.
Did you complete the replacement?
Go to Step 13  -
13 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 2