Charge Mode: Notes

WARNING: This page is about a different car, the 2005 Buick LaCrosse and 2005 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.

The BCM will enter Charge Mode when ever one of the following conditions are met:

Once one of these conditions is met, the generator battery control module will set the targeted generator output voltage to a charging voltage between 13.9 volts and 15.5 volts, depending on battery SOC and estimated battery temperature.