Noise Diagnosis - Auxiliary Blower Motor
WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
Noise Diagnosis - Auxiliary Blower Motor
| Step | Action | Yes | No |
|---|---|---|---|
| DEFINITION: Noise originating from the auxiliary blower motor. | |||
| 1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual |
| 2 |
|
Go to Step 3 | Go to Step 12 |
| 3 | Inspect for excessive vibration at each auxiliary blower motor speed by feeling the auxiliary blower case. Is excess vibration present? |
Go to Step 5 | Go to Step 4 |
| 4 | Listen to the auxiliary blower motor at each blower speed. Is the auxiliary blower motor making a squeaking or chirping noise? |
Go to Step 10 | Go to Step 12 |
| 5 | Inspect the blower motor and the blower motor housing for proper installation. Is the blower motor or the blower motor housing touching the vehicles body and causing the vibration? |
Go to Step 9 | Go to Step 6 |
| 6 |
|
Go to Step 8 | Go to Step 7 |
| 7 | Inspect the auxiliary blower motor for the following conditions:
Did you find any of these conditions? |
Go to Step 10 | Go to Step 11 |
| 8 | Remove the foreign material. Is the action complete? |
Go to Step 11 | - |
| 9 | Install the component so there is no contact with the vehicles body. Is the action complete? |
Go to Step 12 | - |
| 10 | Replace the auxiliary blower motor. Refer to Blower Motor Replacement - Auxiliary (With E59) or Blower Motor Replacement - Auxiliary (Without E59) . Is the repair complete? |
Go to Step 12 | - |
| 11 | Install the auxiliary blower motor. Refer to Blower Motor Replacement - Auxiliary (With E59) or Blower Motor Replacement - Auxiliary (Without E59) . Is the action complete? |
Go to Step 12 | - |
| 12 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Step 2 |