Air Conditioning (A/C) Diagnostics - Pressure Zone D
WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
Air Conditioning (A/C) Diagnostics - Pressure Zone D
| Step | Action | Yes | No |
|---|---|---|---|
DEFINITION: The low side pressure is lower than normal and the high side pressure is higher than normal.
|
|||
| 1 | Were you sent here from the A/C System Performance Test? | Go to Step 2 | Go to Air Conditioning (A/C) System Performance Test |
| 2 |
CAUTION:
Refer to Moving Parts and Hot Surfaces Caution
in Cautions and Notices. Feel the liquid line before the expansion device.Is the liquid line cold before the expansion device? |
Go to Step 3 | Go to Step 8 |
| 3 | Feel along the surfaces of the following high side components:
Did you detect an abrupt drop in temperature along the surfaces of any of the listed components? |
Go to Step 7 | Go to Step 4 |
| 4 |
|
Go to Step 11 | Go to Step 5 |
| 5 | Feel along the surfaces of the following low side components:
Did you feel an abrupt temperature change along the surfaces of any of the listed components? |
Go to Step 7 | Go to Step 6 |
| 6 | Feel along the surfaces of the low and the high side components.
Are the temperatures of these components only mildly warm? |
Go to Step 14 | Go to Step 8 |
| 7 |
|
Go to Step 9 | - |
| 8 |
|
Go to Step 9 | Go to Step 10 |
| 9 | Recharge the A/C system. Refer to Refrigerant Recovery and Recharging . Is the cooling performance improved? |
Go to Step 21 | Go to Step 10 |
| 10 |
|
Go to Step 21 | - |
| 11 | The expansion device is restricted. Replace the expansion device. Refer to Thermal Expansion Valve Replacement . Are metal flakes present? |
Go to Step 12 | Go to Step 13 |
| 12 |
|
Go to Step 18 | Go to Step 20 |
| 13 | If the expansion device was restricted with a brown or black residue, perform the following procedure:
Are the repairs complete? |
Go to Step 21 | - |
| 14 |
|
Go to Step 15 | Go to Step 19 |
| 15 |
|
Go to Step 17 | Go to Step 16 |
| 16 | If the expansion device does not show any signs of damage or debris, perform the following procedure:
Did a large amount of debris collect in the shop towel? |
Go to Step 18 | Go to Step 19 |
| 17 |
|
Go to Step 12 | Go to Step 13 |
| 18 | If a large amount of debris was collected in the shop towel from the suction hose, replace the receiver dehydrator. Refer to Receiver Dehydrator Replacement . Is the repair complete? |
Go to Step 19 | - |
| 19 | Install the suction and the discharge hoses. Refer to Discharge Hose Replacement (w/C60 Compressor) , Discharge Hose Replacement (w/C69 Compressor) , Suction Hose Replacement (w/C60 Compressor) or Suction Hose Replacement (w/C69 Compressor) . Are the repairs complete? |
Go to Step 21 | - |
| 20 |
|
Go to Step 21 | - |
| 21 |
|
Go to Step 22 | Go to Air Conditioning (A/C) System Performance Test |
| 22 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Symptoms - HVAC Systems - Manual |