Air Temperature Actuator
The actuators are 2-wire, bi-directional electric motors that share the same common control circuit. When the operator adjusts the actuators, the control module can only operate one actuator at a time due to the shared common control circuit.
The control circuits use either a 0 or 12-volt value to coordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 12 volts. In order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module reverses the polarity of the circuits to move the actuator in the opposite direction. The HVAC control module determines the door position by counting motor pulses on one of the control circuits. These pulses are small voltage fluctuations that occur when the brush is shorted across 2 commutator contacts as the motor rotates. As the actuator shaft rotates, the HVAC control module monitors the voltage drop across an internal resistance to detect the pulses. The HVAC control module converts the pulses to counts with a range of 0-255 counts. The HVAC control module uses a range of 0-255 counts to index the actuator position.