Battery Sulfation Mode
WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
The BCM will enter this mode when the interpreted generator output voltage is less than 13.2 volts, for 45 minutes. Once in this mode, the BCM will set a targeted output voltage of 13.8 volts, for 5 minutes. The BCM will then determine which mode to enter depending on voltage requirements.