HVAC Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine Idling, A/C ON, Ambient Air Temperature Between 22-27°C (70-80°F)
A/C Request HVAC Yes/No Varies
Recirculation Dr. Position HVAC Counts Varies
Recirculation Dr. Motor Command HVAC Counts Varies
Mode Dr. Position HVAC Counts Varies
Mode Dr. Motor Command HVAC Counts Varies
Defrost Dr. Position HVAC Counts Varies
Defrost Dr. Motor Command HVAC Counts Varies
Driver Temp. Dr. Position HVAC Counts Varies
Driver Temp. Dr. Motor Command HVAC Counts Varies
Psgr. Temp. Dr. Position HVAC Counts Varies
Psgr. Temp. Dr. Motor Command HVAC Counts Varies
Aux. Mode Dr. Position HVAC Counts Varies
Aux. Mode Dr. Motor Command HVAC Counts Varies
Aux. Temp. Dr. Position HVAC Counts Varies
Aux. Temp. Dr. Motor Command HVAC Counts Varies
Evaporator Temp. Sensor HVAC °C/°F Varies
Evaporator Temp. Sensor HVAC Counts Varies
Mode Status HVAC Recirc/Vent/Mix-Blend/Floor/Bi-Level/Defrost Varies
A/C LED HVAC On/Off Varies
Rear Defrost LED HVAC On/Off Varies
Driver Heated Seat Status HVAC Off/Low Heat/High Heat Varies
Passenger Heated Seat Status HVAC Off/Low Heat/High Heat Varies
Blower Motor Switch Position HVAC Off/On but not High Blower/On and High Blower Varies
Aux. Blower Motor Speed Command HVAC Counts Varies
Aux. Blower Motor Switch Position HVAC Aux/Off/1/2/3/4 Varies
Aux. Blower Motor Speed HVAC Counts Varies
PCM Scan Tool Data List 3.5L (LX9)/ECM 3.9L (LZ9)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine Idling, A/C ON, Ambient Air Temperature Between 22-27°C (70-80°F)
A/C Disengage Reason HVAC None/WOT/System Voltage/CKP Learn Active/Engine Run Time/Coolant Hot/Stall Prevention/A/C Pressure/Engine Speed/Trans Engine Speed/A/C Pressure Sensor/Low Voltage/High Voltage/Outside Air Temp/Switched OFF Varies
A/C Off for WOT HVAC Yes/No Varies
A/C Pressure Disable HVAC Yes/No Varies
A/C High Side Pressure HVAC kPa/Psi Varies
A/C High Side Pressure HVAC Volts Varies
A/C Relay Command HVAC On/Off Varies
A/C Relay Circuit History HVAC OK/Open/Short/Invalid State Varies
A/C Request Signal HVAC Yes/No Varies