LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Lucerne CX >> Repair and Diagnosis >> External Pages >> Different car >> Section 185 (Engine Controls - 3.5L - Introduction (2 Of 2)) >> Repair Instructions >> Quick Connect Fitting(s) Service (Metal Collar) >> Removal Procedure

Removal Procedure

WARNING: This page is about a different car, the 2006 Pontiac Montana SV6, 2006 Chevrolet Uplander, and 2006 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Refer to Gasoline/Gasoline Vapors Caution in Cautions and Notices.
    Fig 1: View Of Quick-Connect Fitting Retainer (Metal Collar)
    GM730809Courtesy of GENERAL MOTORS CORP.
  1. Relieve the fuel system pressure before servicing any fuel system connection. Refer to the Fuel Pressure Relief Procedure .
  2. Remove the retainer from the quick-connect fitting.
  3. Fig 2: Blowing Dirt Out Of Fitting (Metal Collar)
    GM12776Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Safety Glasses Caution in Cautions and Notices.
  4. Blow dirt out of the fitting using compressed air.
  5. Fig 3: Releasing Quick Connect Locking Tabs (Metal Collar)
    GM12780Courtesy of GENERAL MOTORS CORP.
  6. Choose the correct tool from the J 37088-A  for the size of the fitting. See Special Tools . Insert the tool into the female connector, then push inward in order to release the locking tabs.
  7. Fig 4: Releasing Quick Connect Locking Tabs (Metal Collar)
    GM12782Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Relieving Fuel Pressure Caution in Cautions and Notices.
  8. Pull the connection apart.
  9. Use a clean shop towel in order to wipe off the male pipe end.
  10. Inspect both ends of the fitting for dirt and burrs. Clean or replace the components as required.