Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
- The ECM detects that the voltage difference between APP sensor 1 and 2 is more than 0.25 volt.
- The ECM detects that the voltage difference between APP sensor 1 and 2 is more than 0.29 volt with a partially pressed pedal.
- The ECM detects that the voltage difference between APP sensor 1 and 2 is more than 1.09 volts with a fully pressed pedal.
- The ECM detects that the APP sensor 1 voltage is more then 1.23 when leaving the idle range and the voltage difference between APP sensor 1 and 2 is more than 0.04.
- Any of the above conditions exist for less than 4 seconds.