LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Allure CX >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Engine Control System & Fuel System - 3.6L - Introduction (2 Of 2)) >> Repair Instructions >> Camshaft Position Actuator Solenoid Replacement - Bank 2 (Left Side) Exhaust >> Removal Procedure

Removal Procedure

WARNING: This page is about a different variant/trim than selected.
  1. Turn the ignition OFF.
  2. IMPORTANT: Do not disconnect the power steering fluid lines/hoses from the reservoir.
  3. Remove the power steering fluid reservoir bolts and reposition the power steering fluid reservoir in order to provide access. Refer to Remote Power Steering Fluid Reservoir Replacement in Power Steering System.
  4. Fig 1: View Of Left CMP Actuator Valve Electrical Connector - Exhaust
    GM1285203Courtesy of GENERAL MOTORS CORP.
  5. Remove the camshaft position (CMP) actuator valve electrical connector.
  6. Fig 2: View Of Left CMP Actuator Valve - Exhaust
    GM1285231Courtesy of GENERAL MOTORS CORP.
  7. Remove the CMP actuator valve bolt.
  8. Remove the CMP actuator valve.