LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Allure CX >> Repair and Diagnosis >> External Pages >> Different car >> Section 19 (Lighting Systems) >> Diagnostic Information and Procedures >> Hazard Lamps Malfunction >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2008 Buick LaCrosse and 2008 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the harness connector at the Driver Information Center (DIC).
  2. Test for less than 10 ohms between the ground circuit terminal 4 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify the scan tool Hazard Switch Signal parameter is Off.
    • If not the specified value, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the BCM.
  4. Install a 3A fused jumper wire between the signal circuit terminal 2 and ground. Verify the scan tool Hazard Switch Signal parameter is On.
    • If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM.
  5. If all circuits test normal, test or replace the DIC.