LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2007 >> Allure CX >> Repair and Diagnosis >> External Pages >> Different car >> Section 16 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> DTC B0164, B0174, B0179, B0510, or B0515 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2008 Buick LaCrosse and 2008 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.
  2. Ignition OFF, test for less than 1.0 ohm of resistance between the appropriate low reference circuit terminal B and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify the appropriate scan tool temperature sensor parameter is greater than 250 counts.
    • If less than the specified range, test the appropriate signal circuit terminal for a short to ground. If the circuit tests normal, replace the HVAC control module.
  4. Install a 3A fused jumper wire between the appropriate signal circuit terminal A and ground. Verify the appropriate scan tool temperature sensor parameter is less than 5 counts.
    • If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  5. If all circuits test normal, test or replace the appropriate temperature sensor.