Circuit Description
The HVAC control module controls the HVAC actuators to regulate the airflow through the HVAC system. Each actuator is a 2 wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use either a 0 or 12 volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module reverses the polarity of the control circuits to move the actuator in the opposite direction.
The HVAC control module determines the door position by counting motor pulses on one of the control circuits. The HVAC control module converts the pulses to counts with a range of 0 to 255 counts.
When a calibration or recalibration procedure is performed, the HVAC control module calculates the door travel range. The HVAC control module compares the total number of pulses to calibrated limits. If the total pulse count is less than or equal to the maximum calibrated limited and more that or equal to the minimum calibrated limit, then the calibration is considered successful.
- Air Flow Control 3 Circuit refers to the mode actuator.
- Air Flow Control 7 Circuit refers to the recirculation actuator.
- Temperature Control 2 Circuit refers to the temperature actuator.