Blower Motor Always On

WARNING: This page is about a different car, the 2004 Pontiac Grand Prix. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Always On

Step Action Value(s) Yes No
Schematic Reference:  HVAC Schematics  
Connector End View Reference: HVAC Connector End Views 
DEFINITION: The blower motor is ON while the HVAC control is in the OFF position.
1 Did you perform the HVAC Diagnostic System Check? - Go to Step 2  Go to Diagnostic System Check - HVAC Systems - Manual 
2
  1. Turn ON the ignition, with the engine OFF.
  2. Turn OFF the HVAC controls.
Is the blower motor OFF?
- Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems Go to Step 3 
3 Disconnect the HVAC control module.
Does the blower motor continue to operate?
- Go to Step 4  Go to Step 6 
4 Inspect or test the blower motor housing and the blower motor speed control circuit in the blower motor harness for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
- Go to Step 9  Go to Step 5 
5 Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
- Go to Step 9  Go to Step 7 
6 Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
- Go to Step 9  Go to Step 8 
7 Replace the blower motor control processor. Refer to Blower Motor Replacement .
Did you complete the replacement?
- Go to Step 9  -
8 Replace the HVAC control module. Refer to HVAC Control Assembly Replacement .
Did you complete the replacement?
- Go to Step 9  -
9 Operate the system in order to verify the repair.
Did you correct the condition?
- System OK Go to Step 3