DTC B1000: Instrument Panel Cluster (IPC) Malfunction: Testing
- If instrument panel cluster diagnostic system check was performed, go to next step. If instrument panel cluster diagnostic system check was not performed, go to INSTRUMENT PANEL CLUSTER DIAGNOSTIC SYSTEM CHECK .
- Using scan tool, clear instrument panel cluster DTCs and retest for DTC . B1000. If DTC B1000 resets, replace instrument panel cluster. See INSTRUMENT PANEL CLUSTER under REMOVAL & INSTALLATION. Using scan tool, clear all DTCs. Recheck system operation.