Instrument Cluster Dimmer Test
- Disconnect instrument cluster C2 connector. Place light switch in "PARK" position. Vary dimmer switch position while making voltage measurements. Connect test light between Gray wire and Black/White wire. If test light brightness varies with dimmer switch position, go to next step. If not, replace dimmer switch.
- Connect test light between Brown wire and Black/White wire. If test light comes on, replace instrument cluster. If test light does not come on, check Brown wire for an open circuit.