LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2025 >> 230i >> Repair and Diagnosis >> External Pages >> Different car >> Section 244 (General Orphan Data (2 Of 2)) >> Only on vehicles with active pedestrian protection

Only on vehicles with active pedestrian protection

WARNING: This page is about a different car, the 2025 BMW M4, 2024 BMW M4, 2023 BMW M4, 2022 BMW M4, and 2021 BMW M4. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Pyrotechnic components. 
Danger! Immobilization period-threatening injuries! 

Deactivating the 48 V electrical system 

Precondition 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
WARNING: Deactivate the 48-V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
NOTE: RISK OF DAMAGE 
Damage to the 48-V battery 
If a 48-V battery that is disconnected from the electrical system is activated, the battery electronics will be damaged. 
  • Only ever activate the 48 V electrical system when the 48 V battery is fully connected up.
NOTE: TECHNICAL INFORMATION 
Observe notes on the 48-V battery. See NOTES ON THE 48-V BATTERY .

Desired state 

Result 

» Absence of voltage  cannot be specified with the Check Control message "48 V electrical system switched off." (1). Work start is not permitted.

Measure

Result 

» The Check Control message reports that 48 V electrical system is switched off.

Measure

"Disconnect the negative battery cable of the 48-V battery" work can be started.