Installing the rain-light-solar-condensation sensor
Check
NOTE:
RISK OF DAMAGE
Damage to silicone surface
A damaged silicone surface can lead to malfunctioning of the rain-light-solar-condensation sensor
Damage to silicone surface
A damaged silicone surface can lead to malfunctioning of the rain-light-solar-condensation sensor
- Do not tap or damage the silicone-coated surface on the rain-light-solar-condensation sensor
- After loosening lock, wait approx. 30 min. at 20°C for silicone surface to relax
- Check the silicone surface (1) and sensor (2) for damage
Result
» Sensor (2) is damaged
Measure
- Replace rain-light-solar-condensation sensor
Result
» Silicone surface is damaged (1)
Measure
- Replace the gel pad
Replacing the gel pad for rain-light-solar-condensation sensors
Result
» Silicone surface (1) and sensor (2) do not show signs of damage
Measure
- Install the rain-light-solar-condensation sensor
- Carefully clean windshield in contact area (1) of rain-light-solar-condensation sensor
- Guide in the rain-light-solar-condensation sensor (2) in the holder and press on the center of the retaining springs (1)
- To lock in place, press down the retaining springs (1) on each side one after the other
Check
- Check contact surface externally for air pockets
Visible shades (1) are not air pockets, rather the optical element of the rain-light-solar-condensation sensor (2). The shades (1) do not represent a functional limitation
Result
» Contact surface exhibits air pockets
Measure