Removing all oxygen sensors
- Unlock the clamps (1).
- Feed out air duct (2) in the arrow direction and remove.
- Unlock lock (1).
- Let the lock (1) engage at the holder (arrow).
- Unlock the locks (1).
- Feed out and remove the clean air pipe (2) for cylinders 4 to 6.
- Unlock plug connection (1) and disconnect.
- Unlock and release the lock (1) with the screwdriver (2).
- Feed the connector (3) in the arrow direction out of the carrier plate and set it to one side.
- Feed the cable (1) out of the clamps (arrows) and set aside.
- Feed the heat shield (1) out of the clamp (2) and place to one side.
- Release the cable tie (1) with a conventional tool.
- Feed out the heat shield (2) in direction of arrow and set it aside.
- Position special tool 0 491 074 (11 7 020)
on the oxygen sensor monitor (1) for cylinders 1 to 3.
- Release the oxygen sensor monitor (1) for cylinders 1 to 3 with special tool 0 491 074 (117 020)
and remove.
- Unlock the locks (1).
- Guide and remove cover (2) in arrow direction.
- Release nuts (1).
- Feed out the positive battery cables (2) from the remote positive terminal (3) and set them aside.
- Feed out the positive battery cables (2) from the clamps (4) and set aside.
- Unlock plug connection (1) and disconnect.
- Unlock the locks (arrows).
- Feed the connector (1) out of the carrier plate and place it to one side.
- Feed out the cable (1) from the holder (2) and set aside.
- Feed out the cable (1) from the clamps (3) and set aside.
- Feed out and remove the clamp (1).
- Position the special tool 0 491 075 (11 7 030)
using the special tool 0 493 751 (11 9 150)
on the Lambda oxygen sensor (1) for the cylinders 4 to 6.
- Release Lambda oxygen sensor for the cylinders 4 to 6 using the special tool 0 491 075 (11 7 030)
and special tool 0 493 751 (11 9 150)
and remove.
- Loosen screws (1).
- Guide out and remove the heat shield (1).
- Unlock the locks (arrows).
- Feed the connector (1) out of the carrier plate and place it to one side.
- Unlock plug connection (1) and disconnect.
- Feed the cable (1) out of the clamps (arrows) and set aside.
- Position the special tool 0 491 074 (11 7 020)
on the Lambda oxygen sensor (1) for the cylinders 1 to 3.
- Release the Lambda oxygen sensor (1) for cylinders 1 to 3 with special tool 0 491 074 (117 020)
and remove.
- Unlock plug connection (1) and disconnect.
- Loosen screws (1).
- Raise the carrier plate (2) slightly.
- Unlock connector (1) using a standard screwdriver (2) and release.
- Feed the connector (1) out of the carrier plate in the arrow direction and set it to one side.
- Loosen nuts (1).
- Feed out and remove the heat shield (2).
- Release nut (1).
- Pull out the positive battery cable (2) from the clamp (3) and set it aside.
- Release nuts (1).
- Loosen screws (2).
- Guide out and remove holder (3).
- Release the clamp (1) with a standard tool (2).
- Prepare the special tool.
Number Description 1 Torque wrench 11 7 030 Wrench socket 11 9 150 Extension - Position special tool 0 491 075 (11 7 030)
and special tool 0 493 751 (11 9 150)
on the oxygen sensor monitor (1) for cylinders 4 to 6.
- Release the oxygen sensor monitor (1) for cylinders 4 to 6 with special tool 0 491 075 (11 7 030)
and special tool 0 493 751 (11 9 150)
and remove.