Evacuate and charge conditioning
Evacuating the air conditioning
Prerequisite
The engine is switched off.
- Carry out the service function:
- Body
- Heating and air conditioning functions
- Drain/fill up refrigerant circuit
- Remove the sealing caps from the refrigerant filler necks.
- Connect the high pressure line of the A/C service station with the vehicle's high-pressure connection (red).
- Connect the low-pressure line of the A/C service station with the vehicle's low-pressure connection (blue).
- Start the suction process on the A/C service station.
- Adhere to an suction time of at least 30 min.
- During suction process, allow the blower of the heating and air-conditioning unit to run at middle blower speed.
- If the vacuum does not remain stable during suction process:
- Run the ABL for leaks in the refrigerant circuit.
- Rectify leaks in the refrigerant circuit.
Charging the air conditioning
Prerequisite
The service function must be active.
The engine is switched off.
Heating and air conditioning system is switched off.
The refrigerant circuit is evacuated and tight.
Vehicle must be positioned on the ground.
Injury hazard!
- Note and follow safety instructions on containers.
- Avoid contact with refrigerant; wear safety goggles and hand protection.
- For additional information see: NOTES REGARDING REFRIGERANT (R134A, R1234YF) AND REFRIGERANT OIL and NOTES FOR REPAIR WORK ON AIR CONDITIONING .
Filling a raised vehicle will result in insufficient filling levels.
In some cases, Sanden SP-A2 refrigerant oil must be injected into the refrigerant circuit.
Check
- Check whether the rate of refrigerant loss as per Table 1 is exceeded.
Table 1 indicates the permitted loss of refrigerant after a specific period of time.
The system is not leaking.
| Table 1 | |||||
|---|---|---|---|---|---|
| Number of years since system last filled | 0-1 | 1-2 | 2-3 | 3-4 | 4-5 |
| Permissible loss [g] | ≤ 30 | ≤ 60 | ≤ 90 | ≤ 120 | ≤ 150 |
Result
» The rate of refrigerant loss as per Table 1 is not exceeded .
Measure
- Top up lost refrigerant.
Do not top up refrigerant oil.
Result
» The rate of refrigerant loss as per Table 1 is exceeded .
Measure
- Top up lost refrigerant.
Top up refrigerant oil according to Table 2 .
Table 2 indicates the amount of refrigerant oil to be added after a specific period of time in the case of an unacceptable loss of refrigerant due to a leak.
| Number of years since last filling | Loss of refrigerant [g] | Top up quantity refrigerant oil |
|---|---|---|
| 0-1 | < 120 | 0 |
| 0-1 | 120-150 | 10 |
| 0-1 | > 150 | 20 |
| 1-2 | < 180 | 0 |
| 1-2 | 180-210 | 10 |
| 1-2 | > 210 | 20 |
| 2-3 | < 240 | 0 |
| 2-3 | 240-270 | 10 |
| 2-3 | > 270 | 20 |
| 3-4 | < 300 | 0 |
| 3-4 | 300-330 | 10 |
| 3-4 | 330 | 20 |
| 4-5 | < 360 | 10 |
| 4-5 | > 360 | 20 |
Check
- Check whether and why parts of the refrigerant circuit have been replaced.
Result
» Version A: Parts of the refrigerant circuit have been replaced as preliminary work for further work or due to gradual leakage (minor leak, e.g. hairline crack).
Version B: Parts of the refrigerant circuit have been replaced due to sudden loss of refrigerant (major leak, e.g. broken pipe due to accident).
Measure
- Add refrigerant oil according to table:REFRIGERANT OIL SPECIFICATION
Version A Version B Air conditioning compressor(1). (1). (1). Evaporator 10 ml 35 ml Air conditioning condenser without integrated desiccant insert 20 ml 35 ml Air conditioning condenser with integrated desiccant insert 40 ml 55 ml Desiccant insert/dryer flask 20 ml 55 ml Per replaced refrigerant line 10 ml 35 ml Safety pressure switch, gaskets 0 ml 0 ml (1) Air conditioning compressor: see 6452, lubricating the air conditioning compressor - Top up determined coolant oil level into the refrigerant circuit.
- Fill the amount of refrigerant as per the nameplate into the refrigerant circuit.
- Disconnect the high pressure line and low pressure line on the vehicle.
- Drain the high pressure line and low pressure line.
- Once again close the refrigerant filler neck on the vehicle with the sealing caps.
| Fill quantity refrigerant R134a/1234yf (G01/G02/G08/G20/G21/G29) | ||
| B47/B57 | ||
| 550 g | ||
| B48/B58TU0 | ||
| 550 g | ||
| B48/B58TU1 | ||
| 550 g | ||