Prepare for the installation of the hydraulic unit
NOTE:
TECHNICAL INFORMATION
Maintain conditions of absolute cleanliness
Maintain conditions of absolute cleanliness
- Check the retaining lugs of the holding clip (1) in the marked area (2) for damage and replace the holding clip where required
- Replace the seal (1) on the hydraulic unit
Parts: Seal
- Thoroughly clean the sealing surfaces on the hydraulic unit and on the cowl