LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2023 >> M240i >> Repair and Diagnosis >> General Information >> OEM General Information >> General Orphan Data (2 Of 2) >> Deactivating the 48 V electrical system

Deactivating the 48 V electrical system

Precondition 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
WARNING: Deactivate the 48-V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
NOTE: RISK OF DAMAGE 
Damage to the 48-V battery 
If a 48-V battery disconnected from the on-board electrical system is activated, the battery electronics are damaged. 
  • Only ever activate the 48 V electrical system when the 48 V battery is fully connected up.
NOTE: TECHNICAL INFORMATION 
Observe notes on the 48-V battery. See additional information NOTES ON THE 48-V BATTERY .