Installing the pressure line between the air conditioning compressor and the air conditioning condenser
- Replace O-rings.
Parts: O-rings.
- Insert the refrigerant line (2) from the top and position it.
- Place the refrigerant line (2) on the air conditioning condenser (5).
- Tighten down screw (4).TIGHTENING TORQUE SPECIFICATIONS
Refrigerant lines to air conditioning condenser/connecting piece M6 tightening torque 13 Nm - Position the refrigerant line (2) on the air conditioning compressor (3).
- Tighten down screw (1).TIGHTENING TORQUE SPECIFICATIONS
Refrigerant line on air conditioning compressor M8 tightening torque 19 Nm - Feed in and install the holder (1).
- Insert the coolant hose (2) into the holder (1).
- Close the holder (1).
Follow-up work
- Refer to INSTALLING THE BRACKET FOR THE DME CONTROL UNIT .
- Refer to INSTALLING THE ENGINE CONTROL UNIT COVER .
- Refer to INSTALLING TENSION STRUT ON SHOCK TOWER .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to EVACUATE AND CHARGE CONDITIONING .
- Refer to CONNECTING ALL BATTERY GROUND LEADS .