Notes On Mechatronics
CAUTION:
Materials harmful to health
.
Contact with fluids harmful to health!
Contact with fluids harmful to health!
- Note and follow safety instructions on containers.
- Conduct all work in appropriate personal protective equipment only.
NOTE:
RISK OF DAMAGE
Damage to the automatic transmission after removal of the mechatronics .
Serious damage to the automatic transmission due to non-compliance with the following tasks:
Damage to the automatic transmission after removal of the mechatronics .
Serious damage to the automatic transmission due to non-compliance with the following tasks:
- Load specific data status with the diagnostic system.
- Use only approved transmission oil.
- After completion of repair work, check the transmission oil level.
NOTE:
RISK OF DAMAGE
Electrostatic discharge .
Damage to or destruction of electrical components .
Electrostatic discharge .
Damage to or destruction of electrical components .
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: 61 35... NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION .