Releasing the refrigerant lines at the air conditioning compressor
Precondition
All the negative battery cables are disconnected.
- Release nut (1) .
- Pull the positive battery cable (2) out and set it aside.
- Unlock plug connection (3)
and disconnect.CAUTION: Residual pressure in the heating and air conditioning system.
Injury hazard!- Wear safety goggles and protective gloves when disconnecting the refrigerant line.
- Close the refrigerant lines with seal plugs.
- Loosen screws (1) .
- Feed out the refrigerant lines (2) and set them aside.
- Close the refrigerant lines (1)
with commercially available seal plugs.
- Close the bores (1) and (2) with commercially available seal plugs.