Installing the bracket for the DME control unit
- Be sure that the bracket (1) for the lower DDE control unit is correctly inserted into the mounts (2).
- Insert the bracket for the DME control unit.
- Secure the cable clips (2).
- Mount the connector (1) on the bracket for the DME control unit.
- Install the bracket (2) for the DME control unit.
- Tighten down screw (1).
TIGHTENING TORQUES SPECIFICATION
| Control unit bracket on the shock tower | ||
|---|---|---|
| Hexagon screw | tightening torque | 8 Nm |
- Insert and install the integrated power supply module (PDM) (2).
- Make sure the locking mechanism (1) engages audibly.
The lock (1) must audibly engage.
- Feed in and install DME control unit (2).
- Ensure the locking mechanisms (1) engage correctly.
The locks (1) must engage audibly.
- Fasten the cable bracket (1) to the bracket (2).
- Secure the clamps (arrows).
- Attach the connector (2) to the holder (3) and lock.
The connector (2) must engage audibly.
- Connect connectors (1) and lock.
The connector (1) must engage audibly.
- Connect connectors (1) and lock.
The connector (1) must engage audibly.
- Connect connectors (1) and lock.
The connectors (1) must engage audibly.
- Connect connectors (1) and lock.
The connectors (1) must engage audibly.
Follow-up work
- Refer to INSTALLING THE ENGINE CONTROL UNIT COVER .
- Refer to INSTALLING TENSION STRUT ON SHOCK TOWER .
- Refer to DISCONNECTING ALL BATTERY GROUND LEADS .