Removing the wiring harness section for the injectors of cylinders 1 to 4
NOTE:
RISK OF DAMAGE
Electrostatic discharge .
Damage to or destruction of electrical components .
Electrostatic discharge .
Damage to or destruction of electrical components .
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: 61 35... NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION
NOTE:
RISK OF DAMAGE
Malfunction or failure of the DME .
Grounding points that are not screwed on may lead to malfunction or failure of the DME .
Malfunction or failure of the DME .
Grounding points that are not screwed on may lead to malfunction or failure of the DME .
- Screw all screw points of the cable ducts on again. Some of the screw points are also grounding points.
NOTE:
TECHNICAL INFORMATION
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
Preliminary work
- Refer to DISCONNECTING ALL BATTERY GROUND LEADS .
- Refer to REMOVING THE ACOUSTIC COVER .
- Refer to REMOVING SUSPENSION STRUT BRACE .
- Refer to REMOVING RIGHT SUSPENSION STRUT BRACE .
- Refer to REMOVING INTAKE SILENCER HOUSING .
- Refer to REMOVING THE RIGHT TENSION STRUT ON THE SHOCK TOWER .
- Refer to REMOVING COVER FOR THE RIGHT DME CONTROL UNIT .
- Refer to REMOVING THE RIGHT UNFILTERED-AIR DUCT .
- Refer to PARTIALLY RELEASING THE RIGHT CHARGE AIR LINE .
- Refer to REMOVING RIGHT CLEAN AIR PIPE .
Wiring harness for the injectors of cylinders 1 to 4
NOTE:
RISK OF DAMAGE
Malfunction or failure of the DME .
Grounding points that are not screwed on may lead to malfunction or failure of the DME .
Malfunction or failure of the DME .
Grounding points that are not screwed on may lead to malfunction or failure of the DME .
- Screw all screw points of the cable ducts on again. Some of the screw points are also grounding points.
NOTE:
RISK OF DAMAGE
Electrostatic discharge .
Damage to or destruction of electrical components .
Electrostatic discharge .
Damage to or destruction of electrical components .
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: 61 35... NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION
NOTE:
RISK OF DAMAGE
Damage to wires when disconnecting connectors and plug connections .
Sheared wires can cause a short circuit .
Damage to wires when disconnecting connectors and plug connections .
Sheared wires can cause a short circuit .
- Do not pull on wires when disconnecting connectors and plug connections.
NOTE:
TECHNICAL INFORMATION
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
If control units are disconnected, fault memory entries and functional limitations may occur.
The fault memory entries must be read out and, if necessary, deleted.
- Unlock the locks (1).
- Guide the cover (1) in direction of arrow out of the bracket (2) and remove.
- Unlock plug connection (1) and disconnect.
- Unlock and disconnect plug connections (2).
- Unlock and disconnect plug connections (3).
- Unlock lock (1).
- Guide out wiring harness section (2) in direction of arrow and remove.
- Unlock the locks (1).
- Guide and remove cover (2) in arrow direction.
- Loosen nut (1).
- Thread out positive battery cable (3) and set it aside.
- Loosen nut (1).
- Thread out positive battery cable (2) and set it aside.
- Loosen screws (1).
- Loosen screws (1).
- Loosen nut (2).
- Remove ground cable.
- Loosen ground pin underneath and unscrew.
- Place positive battery cables, together with cable clip (3), to one side.
- Unlock connector (4) and detach from the rail pressure sensor.
NOTE:
The description is provided only at one component. The procedure is the same for all other components.
- Unlock connector fastener (1) of ignition coil and detach connector (2) from ignition coils of cylinders 1 to 4.
NOTE:
Schematic diagram is for example purposes. Some parts may differ in certain details.
- Unlock and disconnect the connectors (2) from the injectors with a small slotted screwdriver (1).
- Unlock the lock in the direction of the arrow with a small slotted screwdriver (1).
- Disconnect the connector (2) on the connector housing from the injector.
- Unlock and detach connector (1) from injectors.
- Loosen nuts (2).
- Remove ground cable.
- Disconnect the wiring harness section for the injectors of cylinders 1 to 4 (3) from the other wiring harnesses.
- Guide out the wiring harness section for the injectors of cylinders 1 to 4 and remove.