Installing the left intake plenum (cylinder head removed)
- Replace the seal (4)
.
Parts: Seal
- Only during replacement of the intake plenum:
Loosen screws (1) .
Unlock pressure sensor (2) on the retaining tab (3) .
Remove pressure sensor (2) .
Position pressure sensor (2) .
Retaining tab (3) must audibly lock in.
Tighten down screws (1) .
TIGHTENING TORQUE SPECIFICATIONSPressure sensor screw Tightening torque 3 Nm - Position the left intake plenum.
- Tighten down screws (1)
.TIGHTENING TORQUE SPECIFICATIONS
Intake plenum M6 screw Tightening torque 10 Nm - Tighten down screws (2)
.TIGHTENING TORQUE SPECIFICATIONS
Intake plenum M 8 screw Tightening torque 21.4 Nm