LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2021 >> X7 M50i >> Repair and Diagnosis >> External Pages >> Different car >> Section 216 (Cooling System - Repair -- X5 (G05)) >> 17 00 Cooling, Test >> 17 00 039 Vent the cooling system and check for watertightness with the special tool (X5 xDrive 40i, 2019-, X5 sDrive 40i, 2020-) >> Vent the high-temperature coolant system

Vent the high-temperature coolant system

WARNING: This page is about a different car, the 2023 BMW X5, 2022 BMW X5, 2021 BMW X5, 2020 BMW X5, and 2019 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: TECHNICAL INFORMATION 
Immobilization period-long fill of coolant! 
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
NOTE: TECHNICAL INFORMATION 
Filling without  the vacuum filling equipment (watering can filling) is not permitted  .
If this is not observed, there is a risk of component damage or engine damage. The filling specification must  be observed.
It is essential to visually check the vacuum filling equipment before use  to check that it is functioning correctly and clean.
It is not permissible to operate the vehicle if the filling procedure has not been fully completed. Otherwise there may be functional limitations (degradation) or overheating.
A bleeding procedure is required after a part has been exchanged in the cooling system and/or after refilling the cooling system.
NOTE: TECHNICAL INFORMATION 
Before starting the automatic cooling system bleeding procedure, make sure that all coolant circuits  are filled  . If the cooling system bleeding procedure is started while one of the coolant circuits is empty, there is a risk of damage to the electric coolant pump when running it dry.
Make sure that terminal 15 is not disconnected for the bleeding procedure  . Switch on low-beam headlights and hazard warning lights. If the low-beam headlights and hazard warning lights are not switched on, the ignition (terminal 15) will switch off automatically after a certain period of time and interrupt the bleeding procedure.
NOTE: TECHNICAL INFORMATION 
G07 with S4NNA: The air conditioning control panel must be switched off.
NOTE: TECHNICAL INFORMATION 
The electrical fan is activated during the entire cooling system bleeding procedure.
NOTE: TECHNICAL INFORMATION 
The driving dynamics control must not be set to the ECO PRO switch position.

If the low beams and the hazard-warning lights are not  turned on, the ignition (terminal 15  ) turns off automatically after a while and interrupts the bleeding procedure.

G14192861Courtesy of BMW OF NORTH AMERICA, INC.

The engine speed (up to 3500 rpm) and the actuators in the engine cooling system are activated automatically  according to a cooling system bleeding procedure for 11 min.

The cooling system bleeding procedure ends approx. 11 min after  the engine start.

The engine speed reduces  to idle speed.

If the service function is canceled, the cooling system bleeding procedure must  be repeated ("Service function canceled").

NOTE: TECHNICAL INFORMATION 
After the cooling system bleeding procedure, the cooling system is topped up via the maximum mark.
Overfilling the cooling system serves to balance the remaining air in the cooling system. The normal fill level of the coolant is reached during driving.
G14365461Courtesy of BMW OF NORTH AMERICA, INC.