1112 CYLINDER HEAD WITH LID TECHNICAL DATA (X6 sDrive40i, X6 xDrive40i)
1112 TECHNICAL DATA OVERVIEW
| Check for cylinder head watertightness | |
| Temperature of the cylinder head | 60°C |
| Check for cylinder head watertightness | |
| Testing pressure | max. 3.0 bar |
| Cleaning the intake ports | |
| Blast duration with walnut shell granules | Approx. 20 s |
| Blast duration with pure compressed air for the complete blowing out of walnut shell granules | Approx. 10 s |
| Cleaning the intake ports | |
| Operating pressure | 6 bar... 8 bar |
| Cross deviation from flatness | |
| max. 0.05 mm | |
| Longitudinal deviation from flatness | |
| max. 0.10 mm | |